SYSCON CLKOUTUEN addressOffset = 0x0E4

This register updates the clock source of the CLKOUT pin with the new clock after the CLKOUTSEL register has been written to. In order for the update to take effect at the input of the CLKOUT pin, first write a zero to bit 0 of this register, then write a one.

Table 1. SYSCON registerName = CLKOUTUEN addressOffset = 0x0E4
Bit Symbol Value Description Reset value
0 ENA   Enable CLKOUT clock source update 0
    0 No change  
    1 Update clock source  
31:1 - - Reserved -

-->