SYSCON BODCTRL addressOffset = 0x150

The BOD control register selects four separate threshold values for sending a BOD interrupt to the NVIC and for forced reset. Reset and interrupt threshold values listed in SYSCON registerName = BODCTRL addressOffset = 0x150 are typical values.

Both the BOD interrupt and the BOD reset, depending on the value of bit BODRSTENA in this register, can wake-up the chip from Sleep, Deep-sleep, and Power-down modes.

See the LPC81x data sheet for the BOD reset and interrupt levels.

Table 1. SYSCON registerName = BODCTRL addressOffset = 0x150
Bit Symbol Value Description Reset value
1:0 BODRSTLEV   BOD reset level 0
    0x0 Reserved.  
    0x1 Level 1.  
    0x2 Level 2.  
    0x3 Level 3.  
3:2 BODINTVAL   BOD interrupt level 0
    0x0 Reserved  
    0x1 Level 1.  
    0x2 Level 2.  
    0x3 Level 3.  
4 BODRSTENA   BOD reset enable 0
    0 Disable reset function.  
    1 Enable reset function.  
31:5 - - Reserved 0x00

-->