ACMP Connect the comparator output to the SCT

You can use the comparator output function (ACMP_O) to start or stop the SCT or, more generally, create an SCT event. To create an SCT event, connect AMP_O as follows:

  1. Using the switch matrix, connect ACMP_O to a pin. See ACMP Analog comparator pin description.
  2. Using the switch matrix, connect any of the SCT input functions to the same pin. See SCTimer/PWM SCT pin description.

The selected SCT input can now monitor the ACMP_O function.


-->